Wholesale Cheap Price Small and Lightweight 3 Phase Smart Wifi Electric Power Energy Meter

Product Description

Product Display
Product Detail
Product Detail

Technical Specifications

Meter typeDRT-341C MODBUS-CT
Digit length5+2/6+1
Nominal voltage(Un)110V/127V/133V AC / 230/240V AC(option)
Operational voltage(-15% ~ +10%)Un
Insulation capabilitiesAC voltage: 2KV for 1 min / Impulse: 6KV – 1.2µS waveform
Rated current (Ib)1.5(6)A
Maximum rated current (Imax)6/100A
Operational current range0.4% Ib- Imax
Over current withstand30Imax for 0.01s
Operational frequency range50/60Hz ±10%
Internal power consumption≤2W / 10VA
Test output flash rate (RED LED)1000/2000imp/kWh
Pulse output rate1000/2000imp/kWh
Data storeStored for more than 25 years without power
CommunicationModbus RTU/M-Bus

Product Gallery

Gallery 1 Gallery 2 Gallery 3 Gallery 4 Gallery 5 Gallery 6

Company Profile

Our company is an ISO9001 and MID approved global high-tech enterprise, specializing in the designing, developing, manufacturing, and exporting of energy meters (energy/water/gas meters) and energy management systems for more than 28 years. As a member of National Instrument & Meter Associations, we have helped draft the National Standards for Instruments & Meters.

Our production facilities are equipped with advanced technology, including CP40LV SMT machines and high-standard testing laboratories equipped with ESD generators, electrical fast transient generators, and environmental test chambers. All products are CE certificated, with many achieving MID Approval. We currently export over 3,000,000 units annually to markets across Europe, Asia, South America, and Africa.

Certifications

Cert 1 Cert 2

FAQ

1. What should I check if there is no light for the consumption indicator?
Please verify the switch, circuit breaker, fuse, or thermal cut-off. Ensure terminal screws 1 and 4 are tightened, and confirm there is a 230V 50Hz AC voltage across them when power is supplied.
2. Why does the consumption indicator LED not flash?
The LED only flashes when a load is active. If the operating power is very low, the flashing interval will be long, which may appear as if the LED is off.
3. What to do if the register is not counting?
Check if the power supply indicator is on. If the operating power is too low, the pulse interval will be longer. If these are not the issue, please contact technical support for a replacement.
4. How to troubleshoot "No pulse output"?
Ensure the external voltage source (Ui) is 5-27V DC. Verify wiring: connect 5-27V DC to connector 20 (anode) and the signal wire (S) to connector 21 (cathode).
5. What if the pulse output rate is incorrect?
If the pulse output remains incorrect after verifying external connections, please contact technical support for a meter replacement.